    High Water Temperature Of Diesel Generator   Failure characteristics and causes of outlet water high temperature of diesel generator. 1.Air in the water pipe.After the generator started,with the ...
  • Apr 27, 2023
    Comprehensive Cooling Solution For Generator   If the heat dissipation of the generator is not good, it will cause many other faults, such as the power drop,udden shutdown,the peculiar smell, poo...
  • Apr 27, 2023
    Water Enters The Generator   Due to structural constraints, diesel generators can’t be completely waterproof.When the rainy season season comes, generator may be affected by natural disaste...
  • Apr 27, 2023
    Water Cooling Principle Of The Diesel Generator   Cooling water jacket is cast in both the cylinder head and the cylinder block of the diesel engine.After the coolant is pressurized by the water ...
  • Apr 27, 2023
    Diesel generator installation requirements   1.The space around the diesel geneset should be no less than 1 meter. The radiator should be placed with a ventilation window according to the size of...
  • Apr 27, 2023
    Radiator with belt pulley Instruction   Belt installation steps 1.Confirm that the dimension C in the below picture is consistent with the installation dimension of radiator. This size must be gu...
  • Apr 27, 2023
    Prevention Of Generator High Temperature   High water temperature of diesel engine will usually cause  boiling coolant in the radiator , the power decreases, the viscosity of the lubricating...
  • Apr 27, 2023
    Generator in the rainy season   1.In rainy season. In order to prevent lightning strike, the grounding line should be connected to the base of the unit.Open generator set is not recommended in ra...
  • Apr 27, 2023
    Aircooled and watercooled generators difference   Air-cooled generator is a generator with a single-cylinder engine or a double-cylinder engine. One or more large fans are used to force the exhau...
  • May 19, 2023
    Generator Room Air Intake Calculation When diesel generator room adopts clean ventilation,Please calculate the intake air volume and the exhaust air volume as follows:   1.When the generator room...
  • May 19, 2023
    Water level alarm function of diesel unit Water level alarm refers to the water level alarm through the mechanical or magnetic induction method, can sound and light alarm or magnetic alarm at the same...
  • May 19, 2023
    Cooling System-Fan And Wind Scooperon Selection 1.Suction and exhaust fans: For equipment with higher  speed, when the engine is installed in the front part of the equipment, the suction fan can ...